Still sick but no sore throat. Came in to work.
Finished up repairing and cleaning long BNC cables. Had John Harmon help me put them away.
Called Jim Gooding about sending Leslie Chrezan accelerometers for her test in White Sands, NM. He said he should be able to send them to her.
Performed a cal check on one of the VTI1436 cards. You have tell IDeas to do a calibration or it wont be in cal. I ran a precision 5V signal to 8 of the channels. Before I performed the cal, channels were off by as much as 1.5%. Afterwords, they were off only by .16%.
Talked to Brad about next step for the inertial referencing system for the Fast GVT. He gave me a list of things to do. He pointed me to a very good reference book for electrics: "The Art of Electronics", by Horowitz and Hill.
I put the thermocouple cables from the Yuma M777 shock test in 2 plastic bins in storage.
Calculated what I need the resistance op amp in the displacement arm of the circuit in order for us to be able to use the full sensitivity range of the Keyence sensor.